Warning: session_start(): Cannot send session cookie - headers already sent by (output started at /home/content/29/14032429/html/system/database/mysql.php:6) in /home/content/29/14032429/html/system/library/session.php on line 12Warning: session_start(): Cannot send session cache limiter - headers already sent (output started at /home/content/29/14032429/html/system/database/mysql.php:6) in /home/content/29/14032429/html/system/library/session.php on line 12Warning: Cannot modify header information - headers already sent by (output started at /home/content/29/14032429/html/system/database/mysql.php:6) in /home/content/29/14032429/html/index.php on line 179Warning: Cannot modify header information - headers already sent by (output started at /home/content/29/14032429/html/system/database/mysql.php:6) in /home/content/29/14032429/html/system/library/currency.php on line 45 LaserGas III Single Path Gas Analyzers
Specials

LaserGas III Single Path Gas Analyzers

Product Code: NEO
Availability: In Stock
Qty: +
-
  - OR -  

LaserGas III Single Path analyser for oxygen is designed for service in hazardous areas. Based on our third generation LaserGas electronics, the entire instrument is built into compact flameproof enclosures, making it operative in zone 1 and class l division 1 areas.

The LaserGas III SP is our most reliable gas sensor with all electronics designed according to IEC 61508 and SIL 2 (safety integrity level). Based on the fully digital Gen. 3 compact LaserGas electronics, the analyser has a response time of 100 msec.

The LaserGas III SP O2 consists of a transmitter and receiver unit (mounted diametrically opposite each other) to measure the average gas concentration along the optical line-of-sight. Path lengths are typically from 0.5 to 20 meters.

  • SIL 2 Certified
  • Low power < 10 Watt
  • No interference from other gases
  • Stable calibration, no zero drift
  • No gas sampling: In-situ measurement

Detection limit (O2)*                                          100 ppm **

Max.process gas temperature                           1500 oC

Max.process gas pressure                                10 bar abs

Optical path length                                            Typically 0.5 – 20 m

Response time                                                  100 msec

Repeatability                                                    +/- Detection limit or +/- 1% of reading,                                                                                      whichever is greater

Linearity                                                            < 1%