Warning: session_start(): Cannot send session cookie - headers already sent by (output started at /home/content/29/14032429/html/system/database/mysql.php:6) in /home/content/29/14032429/html/system/library/session.php on line 12Warning: session_start(): Cannot send session cache limiter - headers already sent (output started at /home/content/29/14032429/html/system/database/mysql.php:6) in /home/content/29/14032429/html/system/library/session.php on line 12Warning: Cannot modify header information - headers already sent by (output started at /home/content/29/14032429/html/system/database/mysql.php:6) in /home/content/29/14032429/html/index.php on line 179Warning: Cannot modify header information - headers already sent by (output started at /home/content/29/14032429/html/system/database/mysql.php:6) in /home/content/29/14032429/html/system/library/currency.php on line 45 LaserGas III Portable
Specials

LaserGas III Portable

Brand: HTC
Product Code: NEO
Availability: In Stock
Qty: +
-
  - OR -  

The new portable analyzer is compact, lightweight, and battery powered for on-site HF measurement. With an on-board pump and connections for Teflon tubing, the target gas is continuously transferred into the internal measurement cell. Due to the digital low power design, the analyzer is operational for an entire shift with one battery charge.

The analyzer provides reliable operation with instantaneous response and sufficient dynamic range to measure sub ppm and several hundred ppm HF concentrations. In contrast to many other measurement techniques, short-term HF peaks are uncovered with the LaserGas III.

Other gases such as NH3, HCl, and H2S will be implemented consecutively and are available on request.

  • Gen. 3 compact LaserGas electronics
  • Portable close to 2 kg weight
  • Low power < 10 Watt
  • Sub ppm HF detection in seconds
  • No interference from other gases
  • Stable calibration, no zero drift
  • Other gases on request

Specifications
Detection limit (HF)* 50 ppb **

Response time 1 – 2 sec

Repeatability +/- Detection limit or +/- 1% of reading, whichever is greater

Linearity < 1%


Environmental Conditions
Operating temperature -20C to +55C

Storage temperature -20C to +55C

Protection classification IP65


Outputs
Analog output (2) 4 – 20 mA current loop, source or sink

Digital output

10/100 Base T Ethernet (Modbus TCP), USB, RS-485


Ratings
Power consumption Max. 10 W

4 – 20 mA output 500 Ohm max. load impedance, not isolated

Battery Lithium Ion Battery (14.4 V, 5 A, approx. 10 hours usage time per charge)

 

Installation and Operation
Gas inlet / outlet 6 mm SMC one touch fittings (series KQG)

Sample gas flow 3 l/min

Sample inlet pressure +/- 50 mbar G / 0.8 PSIG (higher pressures possible with different pump)

Sample inlet temperature 85 C (185 F)

Calibration Check recommended every 12 months


Security
Laser class Class 1 according to IEC 60825-1, eye safe

CE Certified

EMC Conformant with directive 2004/108/EC

 

PhysicalDimensions

110 x 120 x 250 mm (4.3 x 4.7 x 9.8)

Weight (incl. battery) 2.3 kg (5 lbs)

Display 2.7" colour LCD panel (touch screen)

Sample Cell Teflon coated Aluminium
* Other gases on request
** At gas temperature / pressure = 25C / 1 bar abs.