Specials
Unknown: mysql_query(): The mysql extension is deprecated and will be removed in the future: use mysqli or PDO instead in /home/content/29/14032429/html/catalog/view/theme/marketshop/template/product/product.tpl on line 14Warning: mysql_query(): Can't connect to local MySQL server through socket '/var/lib/mysql/mysql.sock' (2) in /home/content/29/14032429/html/catalog/view/theme/marketshop/template/product/product.tpl on line 14Warning: mysql_query(): A link to the server could not be established in /home/content/29/14032429/html/catalog/view/theme/marketshop/template/product/product.tpl on line 14Warning: mysql_num_rows() expects parameter 1 to be resource, boolean given in /home/content/29/14032429/html/catalog/view/theme/marketshop/template/product/product.tpl on line 15Warning: mysql_fetch_array() expects parameter 1 to be resource, boolean given in /home/content/29/14032429/html/catalog/view/theme/marketshop/template/product/product.tpl on line 17

LaserGas III Single Path Gas Analyzers

Product Code: NEO
Availability: In Stock
Qty: +
-
  - OR -  

LaserGas III Single Path analyser for oxygen is designed for service in hazardous areas. Based on our third generation LaserGas electronics, the entire instrument is built into compact flameproof enclosures, making it operative in zone 1 and class l division 1 areas.

The LaserGas III SP is our most reliable gas sensor with all electronics designed according to IEC 61508 and SIL 2 (safety integrity level). Based on the fully digital Gen. 3 compact LaserGas electronics, the analyser has a response time of 100 msec.

The LaserGas III SP O2 consists of a transmitter and receiver unit (mounted diametrically opposite each other) to measure the average gas concentration along the optical line-of-sight. Path lengths are typically from 0.5 to 20 meters.

  • SIL 2 Certified
  • Low power < 10 Watt
  • No interference from other gases
  • Stable calibration, no zero drift
  • No gas sampling: In-situ measurement

Detection limit (O2)*                                          100 ppm **

Max.process gas temperature                           1500 oC

Max.process gas pressure                                10 bar abs

Optical path length                                            Typically 0.5 – 20 m

Response time                                                  100 msec

Repeatability                                                    +/- Detection limit or +/- 1% of reading,                                                                                      whichever is greater

Linearity                                                            < 1%

Write a review


Your Name:


Your Review: Note: HTML is not translated!

Rating: Bad           Good

Enter the code in the box below: